PRIMA Bowie-Dick Test Pack for Steam Autoclaves - Daily Monitoring for Pre-Vacuum Sterilizers 134°C / 121°C

€1.94 €1.60
Product code: 0124
In stock
Description
The PRIMA Bowie-Dick Test Pack is designed for daily performance testing of pre-vacuum steam sterilizers. It verifies the efficiency of air removal and steam penetration throughout the load, providing a reliable visual confirmation of the sterilization cycle’s effectiveness. This test is widely used in hospitals, laboratories, dental clinics, and sterilization departments to ensure proper autoclave function under standardized conditions. The pack includes: • One white fill paper (115 mm x 125 mm) to simulate porous loads and ensure even steam distribution. • One printed test sheet with a central sterilization indicator designed to react precisely when specific parameters of time, temperature, and pressure are achieved. The indicator ink used for printing contains the following components (in ppm levels): • Water - 35% (CAS # 7732-18-5) • Diacetone alcohol - 3% (CAS # 123-42-2) • Proprietary mixture - 62% (CAS # N/A) The formulation does not include substances classified as hazardous at concentrations that would require special consideration under EC directives. The test pack is suitable for use in pre-vacuum steam sterilizers operating at: • 134°C for 3.5 minutes • 121°C for 15 minutes After the sterilization cycle, the test sheet exhibits a clear color change that indicates whether air removal and steam penetration were properly achieved. The color pattern should be compared to the reference chart provided on the back of the package. Instructions for use: 1. Place the Bowie-Dick Test Pack in the center of the sterilizer chamber, ideally on the lowest shelf, where air removal is most challenging. 2. Run the standard cycle (134°C / 3.5 min or 121°C / 15 min). 3. After the cycle, open the pack and observe the color change on the test sheet. A uniform change confirms complete air removal and consistent steam penetration. Key features: • Indicator color before exposure: blue. • Provides a clear and uniform visual response for easy interpretation. • Ready-to-use disposable test pack - no assembly required. • Compatible with all standard pre-vacuum steam sterilizers. The Bowie-Dick Test Pack provides immediate visual evidence of inadequate air removal, air leaks, vacuum pump malfunction, non-condensable gases, and wet steam issues. It ensures the ongoing verification of sterilizer performance in accordance with international testing standards. The PRIMA test pack represents a consistent, easy-to-use solution for daily verification of autoclave performance, helping maintain the reliability of sterilization processes in professional environments where safety and precision are required.
Specifications
More Information
MPN0124
Add a review
Write Your Own Review
You're reviewing:PRIMA Bowie-Dick Test Pack for Steam Autoclaves - Daily Monitoring for Pre-Vacuum Sterilizers 134°C / 121°C